
Regarding the application of fireproof and thermal insulation, in foreign countries, the general specification requires that the thermal insulation system and thermal insulation material be used for combustion performance and fire endurance test (taking into account the flue gas and toxicity during combustion), and be divided into several grades. The range of applicable systems and materials different. The polyphenylene board external insulation thin plastering system adopted for more than 85% of domestic projects is prohibited in more than 20 states. In the United Kingdom, buildings outside 18m are forbidden to use polystyrene thermal insulation systems. In Germany, buildings above 22m are also prohibited from using polystyrene systems. Therefore, polystyrene insulation systems have rarely been used throughout Europe and the United States.
From the point of view of the European insurance company, it is no longer necessary to insure buildings with polystyrene insulation systems. In China, although the country's JG 149-2003 "Expansion polystyrene board thin plaster external insulation system", must use flame-retardant polystyrene insulation board; in JG 158-2004 "polystyrene powder particles outside the wall The external thermal insulation system makes clear provisions on the fire reactivity of the system (should not be ignited, and the thickness of the test piece does not change by more than 10% after the end of the test). However, the selection of fire insulation barriers for different insulation systems and the selection of the insulation material on the side of the door behind the wall of the system, and the lack of clear regulations on the choice of the insulation system for high-level insulation systems. Although at the end of 2009, the Provisional Regulations on Fire Protection for Civil Building Exterior Insulation Systems and Exterior Wall Decoration jointly issued by the Ministry of Construction and the Ministry of Public Security had further stipulated provisions, there were many violations in the actual projects on the ground. Post-release building fires are still commonplace. Therefore, on March 14, 2011, the Ministry of Public Security issued the "Notice on Further clarification of the requirements relating to the fire supervision and management of exterior thermal insulation materials for civil buildings", which stipulates that external wall insulation materials must be Class A non-combustible materials.
Red Laser
Red lasers include DPSS (diode-pumped solid-state) Laser and diode laser. This series laser include 3 series: high power and stability, low noise and Single Frequency Laser. Free space or fiber-coupled (SM fiber, MM fiber, homogenization fiber) output available. They are widely used in bioengineering, fluorescent substance, raman spectra and so on. Following wavelength are available for red laser:
â—†Diode-pumped All Solid-state Red Laser
604 nm 607 nm 612 nm 622 nm 639 nm 640nm 642 nm 650 nm 656.5 nm 666 nm 671 nm 689 nm 721 nm
â—†Diode Red Laser
627 nm 635 nm 637nm 640 nm 642 nm 650nm 655 nm 660 nm 665 nm 680nm 685 nm 690 nm 705 nm 730 nm 750 nm 760 nm
- Red High Power Laser: power >100 W;
- Red High Stability Laser: stability <0.1%;
- Red Low Noise Laser: noise <0.25%;
-
Red Single Longitudinal mode Laser: line width <0.00001 nm.
Red Laser,Pulsed Red Laser,Red Laser Pointer,Red Laser Beam
Changchun New Industries Optoelectronics Technology Co., Ltd. , https://www.lasersciences.com