Veterinary Automatic Chemistry Analyzer (Chemo 200V)

Model NO.: Chemo 200V
Origin: China
HS Code: 90278090
Model NO.: Chemo 200V
Origin: China
HS Code: 90278090
Veterinary Automatic Chemistry Analyzer(Chemo 200V)
Model: Chemo 200v

Specifications:
· Assay methods: End Point, Kinetic, Fix time etc.
· Principle: Photoelectric colorimetry
· Light Source: Halogen lamp 12V/20W
· Photometry range: 0~3.2Abs
· Resolution: 0.0001Abs
· Wavelength: 340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm
· Throughput: 200 tests/hour
· Reagent tray: 60 reagent positions (include1detergent position, 1 dilution position)
· Sample tray: 71sample positions, standard, QC, STAT positions
· Reaction tray: 120 reaction cuvettes
· Sample volume: 2~100ul, with 0.1ul increment
· Reagent volume: R1: 10~500uL, R2: 10~500uL, with 0.5uL increment
· Minimum reaction volume: 150uL
· Maximum reaction time: 10 minutes
· Water Consumption: 5L/hour under working status
· Clean unit: 8-step auto-washing system with detergent
· Calibration: Calibration reset, select best test point by reaction curve, no need second calibration Line/non-line; Multi-standards assay
· Control rules: Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for each ifem, analyxing and printing QC analysis diagram
· Temperature control: Incubator 37± 0.1º C
· Power supply: AC 230(1± 10%)V, 50/60Hz, 500VA
· Ambient: Operating temperature: 10~30º C
Relative humidity: ≤ 85%
Atmospheric pressure: 86~106kPa

Features:
· 24 hour non-stop cooling system to ensure reagent at 2-8º C
· Durable ceramic syringes to ensure accuracy & precision
· High accurate optical system
· Collision protection in both vertical and horizontal directions, stop & alarm automatically once touching barrier, not affect former tests
· Automatic eligible cuvettes detection & selection
· Select best test point by reaction curve, create new factor automatically
· Support LIS interface

Accurate Sampling(Sample/Reagent) System:
· Collision protection
· Liquid level detection
· Internal and external probe washing
· Probe depth adjustment automatically

[High performance mixer design]
· Bsence of cross contamination
· Optimal homogenization in minimum time
· Mixing immediately after dispensing of sample and the second reagent

Stable Optical System:
· High accurate, close, static state optical system
· Spot photometry with high speed digital transmission system
· Durable cuvettes
· 8-step auto-washing system with detergent and deion-water to ensure cuvettes clean and decrease cross contamination
· 120 reaction cuvettes located in a constant temperature incubator
· Low consumption, open reagent design

Multi-function sample/reagent tray:
· 60 reagent positions, support 25mL, 50 mL reagent bottle type.
· 45 sample positions including routine, stat, control and standard
· Various primary tubes and special cups can be used
· Up to 20 virtual sample tray can be programmed
· 24 hours nonstop cooling system with peltier element

Dynamic and real time display of running status:
· Running status of reagent tray, sample tray and reaction tray
· Real time monitoring of reagent residual volume
· Intelligent carry over setting to adjust test sequence, STAT test priority
· Probe depth adjustment automatically
· Real time monitoring of reaction curve
· Real time diagnosis of system working status Veterinary Automatic Chemistry Analyzer(Chemo 200V)
Model: Chemo 200v

Specifications:
· Assay methods: End Point, Kinetic, Fix time etc.
· Principle: Photoelectric colorimetry
· Light Source: Halogen lamp 12V/20W
· Photometry range: 0~3.2Abs
· Resolution: 0.0001Abs
· Wavelength: 340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm
· Throughput: 200 tests/hour
· Reagent tray: 60 reagent positions (include1detergent position, 1 dilution position)
· Sample tray: 71sample positions, standard, QC, STAT positions
· Reaction tray: 120 reaction cuvettes
· Sample volume: 2~100ul, with 0.1ul increment
· Reagent volume: R1: 10~500uL, R2: 10~500uL, with 0.5uL increment
· Minimum reaction volume: 150uL
· Maximum reaction time: 10 minutes
· Water Consumption: 5L/hour under working status
· Clean unit: 8-step auto-washing system with detergent
· Calibration: Calibration reset, select best test point by reaction curve, no need second calibration Line/non-line; Multi-standards assay
· Control rules: Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for each ifem, analyxing and printing QC analysis diagram
· Temperature control: Incubator 37± 0.1º C
· Power supply: AC 230(1± 10%)V, 50/60Hz, 500VA
· Ambient: Operating temperature: 10~30º C
Relative humidity: ≤ 85%
Atmospheric pressure: 86~106kPa

Features:
· 24 hour non-stop cooling system to ensure reagent at 2-8º C
· Durable ceramic syringes to ensure accuracy & precision
· High accurate optical system
· Collision protection in both vertical and horizontal directions, stop & alarm automatically once touching barrier, not affect former tests
· Automatic eligible cuvettes detection & selection
· Select best test point by reaction curve, create new factor automatically
· Support LIS interface

Accurate Sampling(Sample/Reagent) System:
· Collision protection
· Liquid level detection
· Internal and external probe washing
· Probe depth adjustment automatically

[High performance mixer design]
· Bsence of cross contamination
· Optimal homogenization in minimum time
· Mixing immediately after dispensing of sample and the second reagent

Stable Optical System:
· High accurate, close, static state optical system
· Spot photometry with high speed digital transmission system
· Durable cuvettes
· 8-step auto-washing system with detergent and deion-water to ensure cuvettes clean and decrease cross contamination
· 120 reaction cuvettes located in a constant temperature incubator
· Low consumption, open reagent design

Multi-function sample/reagent tray:
· 60 reagent positions, support 25mL, 50 mL reagent bottle type.
· 45 sample positions including routine, stat, control and standard
· Various primary tubes and special cups can be used
· Up to 20 virtual sample tray can be programmed
· 24 hours nonstop cooling system with peltier element

Dynamic and real time display of running status:
· Running status of reagent tray, sample tray and reaction tray
· Real time monitoring of reagent residual volume
· Intelligent carry over setting to adjust test sequence, STAT test priority
· Probe depth adjustment automatically
· Real time monitoring of reaction curve
· Real time diagnosis of system working status

Cosmetic Tin Box

Now most industries are moving from traditional paper and plastic packaging to Iron Box packaging. The degree of sophistication and beautification of iron box packaging is not comparable to other packaging. Cosmetics are the daily necessities that every woman will use more or less now. It is an irresistible temptation for women to add an exquisite iron box package to cosmetics. The fierce competition in the cosmetics market has also made great changes in the use and design of cosmetic iron boxes. The designer expresses the extension of cosmetics, shakes the mood of consumers, and promotes the brand value and market sales.


Cosmetics are usually used as packaging products in close contact with beauty products. Traditional paper boxes and plastic packaging are inconvenient for transportation, which is easy to squeeze the products during transportation, and may lead to damage in serious cases. The iron can packaging is very convenient for the transportation of cosmetics because of its extensibility, oxidation resistance, and resistance to breakage. Therefore, the cosmetics iron box packaging is very popular for the public!

Cosmetic Tin Box,Eye Shadow Box,Face Pack Box,Tin Box For Cosmetic

Dongguan Tielangtou Hardware Products Co., Ltd , https://www.nbtinboxtlt.com